Share DECA's profile
 
 
 
DECA
 
 
 
DECA's stats
 
Reviews
  • Review count
    0
  • Helpfulness votes
    0
  • First review
    None
  • Last review
    None
  • Featured reviews
    0
  • Average rating
    0
 
Reviews comments
  • Review comment count
    0
  • Helpfulness votes
    0
  • First review comment
    None
  • Last review comment
    None
  • Featured review comments
    0
 
Questions
  • Question count
    0
  • Helpfulness votes
    0
  • First question
    None
  • Last question
    None
  • Featured questions
    0
 
  • Answer count
    104
  • Helpfulness votes
    11
  • First answer
    June 3, 2013
  • Last answer
    August 11, 2014
  • Featured answers
    0
  • Best answers
    1
 
 
DECA's Reviews
 
DECA has not submitted any reviews.
 
DECA's Review Comments
 
DECA has not submitted comments on any reviews.
 
DECA's Questions
 
DECA has not submitted any questions.
 
DECA's Answers
1 2 3 4 5 ... 11 next>>
 
Thermocouple Thermometer, Thermocouple Type Type K, Number of Inputs 2, Probe Connector Mini-Type, Temp. Range (F) -200 Degrees to 1999 Degrees F, Temp. Range (C) -200 Degrees to 1360 Degrees C, Accuracy +/-0.3 Percent (+2 Degrees F/+1 Degrees C), Display Backlit 3 Line LCD, Resolution 0.1 Degrees , 1 Degrees , Sampling Rate -, Battery Type (6) AAA, Auto Power Off Yes, Data Hold Yes, Memory Min/Max, Standards CE, Includes Built In Stand, (2) Probes, Protective Holster, Instructions
 

Does this thermocouple endure organic solvents?

like dichloromethane
According to the manufacturer these thermocouples should not be used in any type of wet environment. The fluid will wick into the insulation and compromise the accuracy of the readings. For use in fluid a stick type probe should be used and in solvent a stainless steel probe is best. Item number 19L886 would be used in applications involving solvents. Thanks for using Grainger Ask & Answer.
1 week, 4 days ago
by
DECA
 
Battery Charger, Battery Type Li-Ion, Charger Input Voltage 120VAC, Number of Ports 3, For Use With Milwaukee(r) M28(TM) Li-Ion, 18.0V Li-Ion and NiCd Batteries
 

How long to recharge a used battery?

According to the manufacturer, this charger will charge all Milwaukee slide on batteries in 1 hour or less. Specifically it states 45 minutes for NiCd batteries and 60 minutes for Li-ion batteries. The condition of the battery may affect charging times. Thanks for using Grainger Ask & Answer.
1 week, 4 days ago
by
DECA
 
Pipe Inspection Borescope, Shaft Length (In.) 1176, Shaft Dia. (In.) 1.1, Observation Depth 10mm to Infinity, Features (2) 90 degree Elbow Bends Turning Capability, Includes 72 Ft Probe,Monitor,Reel,(2) Centering Accessories, li-ion Rechargeable Battery and Charger, SD Card, Blow Mold Case and Manual, Manufacturers Warranty Length 1 Year
 

The answer from the manufacturer stated that this scope was designed for 2-6 inch pipe. Would there be any issue using this for 8-12inch piping?

This unit can be used with the wider piping however there would be a reduction in its performance. The angel of the camera lens allows you to see out to the edges of a 6 inch pipe. Using it in an 8-12 inch pipe would mean that you may miss 2-6 inches of the pipe. There may also be less light available due to the larger volume of space. Thanks for using Grainger Ask & Answer.
1 week, 4 days ago
by
DECA
 
Digital Multimeter, Full Size, Max. AC Volts 600, Max. DC Volts 600, Max. AC Amps 10, Max. DC Amps 10, Max. Ohms 20 megaohm, Basic DC Accuracy +/-0.5 Percent, Counts 2000, Battery Type 9V Alkaline, Safety Rating CAT III 600V, Audible Continuity Yes, AC Response Average, Display LCD, Temp. Range -4 to 1400 Degrees F (-20 to 760 Degrees C), Special Features 1.5V and 9V Battery Test Under Load, Diode Test Yes, Auto Power Off Yes, Includes Battery, Type K Bead Wire Probe, Test Leads, Instructions
 

testing large batteries

I am a mechanic for the post office. We have tow trucks and forklifts that use 24 and 36 volt batteries respectively. We need a load tester to help us determine when a bettery is good or bad. Please advise.
Grainger does carry a handheld battery tester that will work with 12V, 24V, 36V batteries. It is our item number 12V183. It will handle auto batteries up to 650 cold cranking amps and truck batteries up to 1700 cold cranking amps. Thanks for using Grainger Ask & Answer.
1 week, 4 days ago
by
DECA
 

do you have 5/16 offset nutdriver?

We do not offer an offset nut driver as a standalone item. We do carry a ratcheting driver kit that would perform similarly. It is item number 2MRT4. Thanks for using Grainger Ask & Answer.
4 weeks, 1 day ago
by
DECA
 
Hammer Drill Bit, Shank Shape Round, Number of Cutter Heads 2, Bit Dia. 3/4 In., Drilling Length 10 In., Overall Length 12 In., Shank Size 3/4 In.
 

I WANT TO KNOW FOR I CAN USED THIS HCBG23HAMMER DRILL BILT, IF IS GOOD FOR METAL, WOOD OR CONCRETE

This drill bit is a carbide tipped hammer drill bit that is generally used for drilling into stone, concrete and hard tile. Generally speaking these bits are not used for metal and wood. Thanks for using Grainger Ask and Answer
4 weeks, 1 day ago
by
DECA
 
Pressure Washer, Cold, 2 HP, Operating Pressure 1900 psi, Flow Rate 2.1 gpm, Duty Rating Heavy, Volts/Phase 120V/1-Phase, Amps AC 20, Detergent Injection Detergent Tank, Plug Type GFCI, Height 23 In., Width 15-7/10 In., Length 31-1/2 In., Hose Dimensions 5/16 In. x 30 ft., Usable Hours per Week 10 to 20, Pump Type Triplex Plunger, Piston Material Ceramic, Water Output Temp. 140 Degrees F, Net Weight 88 lb., 1 Year Warranty
 

What is the output water temp of 140F reffering to?

The outlet water temp of 140° refers to the maximum temperature of water that can be used with this pressure washer. The manufacturer list it as the max inlet water temp. Thanks for using Grainger Ask and Answer.
4 weeks, 1 day ago
by
DECA
 
Thermocouple Thermometer, Number of Inputs 1, Probe Connector Permanent, Temp. Range (F) -58 Degrees to 572 Degrees F, Temp. Range (C) -50 Degrees to 300 Degrees C, Accuracy +/-1 Degrees C Between -20 Degrees and 100 Degrees C, Display Backlit 3 Line LCD, Resolution 0.1 Degrees (-20 Degrees and 200 Degrees ), Data Logging 10 Points, Data Hold Yes, Memory Min/Max, NIST Calibration Certificate
 

Can I calibrate this instrument daily?

This unit is not able to be calibrated by the user. It is calibrated by the manufacturer and certified by the NIST, meaning user calibration would not be needed. Thanks for using Grainger Ask and Answer.
4 weeks, 1 day ago
by
DECA
 
Level Gauge, Tank, Tank Depth 22 In., Extension Length 0, Connection Size 2 In. NPT, Calibration Unit Material Inner Glass/Outer Plastic, Calibration Unit Increments Eighths of a Tank, Gasket Material Viton, Bushing Material PVC, Assembly Nut Material PVC, Rod Material PEEK, Rivet Material PVC, Float Material HDPE Plastic, Float Dia. 1.125 In, Temp. Range -20 to 120 Degrees F, Pressure Rating 70 PSI, Manufacturers Warranty Length 1 Year
 

Will this fit a 16in Dia x 22in high drum and can it be used for

12.5% liquid bleach Hypochlorite solution? If not can you suggest an appropriate gauge?
This gauge will fit a 22" drum with a 2" NPT fitting. The manufacturer lists : "Sulphuric Acid, Bleach, Hydrochloric Acid, Acetone, Chlorine, Caustics, and more" as acceptable chemicals for this gauge which should work for your application. Thanks for using Grainger Ask and Answer.
4 weeks, 1 day ago
by
DECA
 
V-Belt Pulley, Bore Type Fixed Bore, Material Cast Iron, Number of Grooves 1, Bore Dia. 7/8 In., Outside Dia. 4.95 In., 3L Belt Pitch Dia. 4.36 In., 4L, A, or AX Belt Pitch Dia. 4.7 In., 4LA or A Belt Pitch Dia. 4.7 In., Fits Shaft Dia. 7/8 In., None Bushing Required, Construction Spoked, Set Screw Included Yes, For Use With 3L, 4L or A Type V-belts
 

Does this pulley have a keyway? If so what is the proper keyway part#.

This pulley does have a 3/16" keyway, Grainger item number 5WE41 would work as the prorer key for that size. Thanks for using Grainger Ask and Answer.
1 month ago
by