Share MrElectro1's profile
 
 
 
MrElectro1
 
 
 
MrElectro1's stats
 
Reviews
  • Review count
    0
  • Helpfulness votes
    0
  • First review
    None
  • Last review
    None
  • Featured reviews
    0
  • Average rating
    0
 
Reviews comments
  • Review comment count
    0
  • Helpfulness votes
    0
  • First review comment
    None
  • Last review comment
    None
  • Featured review comments
    0
 
Questions
  • Question count
    0
  • Helpfulness votes
    0
  • First question
    None
  • Last question
    None
  • Featured questions
    0
 
  • Answer count
    1735
  • Helpfulness votes
    116
  • First answer
    April 26, 2012
  • Last answer
    April 18, 2014
  • Featured answers
    0
  • Best answers
    11
 
 
MrElectro1's Reviews
 
MrElectro1 has not submitted any reviews.
 
MrElectro1's Review Comments
 
MrElectro1 has not submitted comments on any reviews.
 
MrElectro1's Questions
 
MrElectro1 has not submitted any questions.
 
MrElectro1's Answers
1 2 3 4 5 ... 174 next>>
 
Grainger Item #: 24W596
Linear Fluorescent Lamp, Lamp Shape T12, Diameter 1-1/2 In., Length 48 In., Base Type Medium Bi-Pin (G13), Start Type Rapid, Lamp Designation F34/CX41/WM/ECO, 34 Watts, Lamp Tone Cool, Color Temp. 4100K, CRI 87, Initial Lumens 2500, Mean Lumens 2200, Average Life 20, 000 hr., No Shatter-Resistant, Meets 2012 Lighting Legislation Energy Standards, General Purpose. Only shipped in quantities of 30.
 

is there a T12 26" fluorescent mediem bypin tube (daylight)

Unfortunately Grainger does not currently stock a 26" T12 lamp.

Thank you for using Grainger Ask & Answer
1 day ago
by
MrElectro1
 
Grainger Item #: 24C864
Ring Terminal, Insulation Type Noninsulated, Wire Range 22 to 16 AWG, Stud Size #6, Max. Temp. 1200 Degrees F, Max. Voltage 600, Overall Length 0.49 In., Seam Butted, Connection Material Nickel Plated Copper, Connection Type Crimp
 

Is there a mil spec associated with the Ring Terminal, #6, 22-16 AWG

Unfortunately Grainger does not currently have a mil spec number for this ring terminal.

Thank you for using Grainger Ask & Answer
1 day ago
by
MrElectro1
 
Grainger Item #: 24W596
Linear Fluorescent Lamp, Lamp Shape T12, Diameter 1-1/2 In., Length 48 In., Base Type Medium Bi-Pin (G13), Start Type Rapid, Lamp Designation F34/CX41/WM/ECO, 34 Watts, Lamp Tone Cool, Color Temp. 4100K, CRI 87, Initial Lumens 2500, Mean Lumens 2200, Average Life 20, 000 hr., No Shatter-Resistant, Meets 2012 Lighting Legislation Energy Standards, General Purpose. Only shipped in quantities of 30.
 

is there a T12 26" FLUORESCENT

Unfortunately Grainger does not currently stock a 26" T12 lamp.

Thank you for using Grainger Ask & Answer
1 day ago
by
MrElectro1
 
Grainger Item #: 39P790
Emergency Stop Push Button, Non-Illuminated, 30mm, Maintained 2 Position Push/Pull, Type of Operator 40mm Dia. Mushroom, Contact Form 1NC, Bezel Chrome Plated Zinc Die-Cast, Color Red, NEMA Rating 3, 3R, 4, 4X, 12, 13, IP Rating 10, Legend Emergency Stop, Standards UL, CE, CSA, Terminal Connection Screw Clamp
 

Is this compatible with the Mitek EasySet Component Saw?

Please call us at 1-800-Grainger so we can discuss your your installation requirements in greater detail.

Thank you for using Grainger Ask & Answer
1 day ago
by
MrElectro1
 

what type cable and wire use for power supply to fire damper actuator,230 ac,q.13amp,23watts

i did install fire damper actuator his rating 230v ac,0.13amp,23 watt i have no knowledge for this this type equipement whic type cable use for power supply please help me.give cable and wire details.
Please call us at 1-800-Grainger so we can discuss your wiring installation in greater detail.

Thank you for using Grainger Ask & Answer
1 day ago
by
MrElectro1
 
Grainger Item #: 2MV47
Phase Converter, Static, Input Voltage 208-242, Output Voltage 208-242, Input Phase AC 1, Output Phase AC 3, Input (Amps) 15, Output Amps 9.6, Output HP 1-3, Depth (In.) 2-5/8, Width (In.) 5-1/8, Height (In.) 9-1/2, HP Range 1 to 3, Knockout Size (In.) 1/2, Motor Load Rating 2/3
 

We have a 240 single phase supply. We are needing to run a 1 hp motor with 208 volt 3 phase. What would be the best converter to use?

One converter will not be sufficient. You will also need a buck boost transformer to achieve the 208v as well. Please call us at 1-800-Grainber so we can discuss your options in greater detail.

Thank you for using Grainger Ask & Answer
1 day ago
by
MrElectro1
 

I need a 240 or 230 volt screw-in bulb. It looks like a regular bulb in your house.

Unfortunately Grainger does not currently stock a 230v A style incandescent lamp.

Thank you for using Grainger Ask & Answer
1 day ago
by
MrElectro1
 
Grainger Item #: 2E022
Enclosed Indoor 24 Hour Timer, Contact Form DPST, Normally Open, Timer Input Voltage 120 Volts, Maximum Time Setting 23 Hours, Minimum Time Setting 1 Hours, Number of Trippers Included 2, Maximum On/Off Cycles 12, Contact Power Rating @ 240VAC 5 HP, Contact Power Rating @ 120VAC 2 HP, Voltage Rating 125 Volts, Current Rating 40 Amps, Day Skipper No, Enclosure Type Steel Indoor, Extra Trippers 2E054, Length 7.8 Inches, Width 5.0 Inches
 

What is Digital alternatives for this timer?

Is this Item # 6KFF6 will work? Or any yous suggestion. Thanks
6KFF6 may work as an alternative; 4JNE5 is a closer match though.

Thank you for using Grainger Ask & Answer
1 day ago
by
MrElectro1
 
Grainger Item #: 3BA74
Miniature Incandescent Bulb, Trade Number 194, Lamp Shape T3 1/4, Base Type Wedge (W2.1x9.5d), 4 Watts, 14 Voltage, 270mA Current Drawn, Average Life 2500 hr., 25 Initial Lumens, Max. Overall Length 1.06 In., Lamp Dia. 0.40 In., Standards Meets 2012 Lighting Legislation Energy, Package Quantity 2
 

2005 mustang instrument cluster bulb

Which bulb do I need?
Please call us at 1-800-Grainger with the voltage, wattage and base type of your current lamp.

Thank you for using Grainger Ask & Answer
1 day ago
by
MrElectro1
 
Grainger Item #: 2PAR7
Hour Meter, LCD, Time Range 0 to 99, 999 Hours, Bezel Face 2.22 In, Bezel Face Type Flush Round, Elapsed Time To 99999.9 Hr, Voltage 4.5 to 28 VDC, Number of Digits 6, Display Units Hours and Tenths, Bezel to Back Length 1.42 In, Ambient Temp Range -22 to 149 F, Material of Construction ABS, Reset Type Remote Signal, Temp Range -22 to 149 F, Fits 2.0 In Diameter Opening, Mounting Method Flange, Terminal Type Spade
 

which terminals do you use

has terminals on the back which ones do you use,, no instructions were included
According to the manufacturer, P would get your positive voltage, N would get your negative voltage, I will be from a pulse counter and R will be for your reset input. If you call us at 1-800-Grainger, we would be happy to provide you with a copy of this wiring diagram.

Thank you for using Grainger Ask & Answer
1 day ago
by